Related products
-
Perfect Femoral Nail – Cannulated (Long) for Left Leg
Use 4.8mm Locking Screw for Standard Locking
Use 6.35mm Hip Screws for Recon Locking
Note: Distal Jig will work upto the length of 440mm. For longer nails C arm is required for Distal Locking. -
Perfect Tibial Nail Implants Set
AS101 – Perfect Tibial Nail Implants Set Set Consisting of : Units Tibial Nails 8.0mm Dia 1 Each Length 255, 270, 285, 300, 315, 330, 345, 360, 375mm 9 9mm Dia 1 Each Length 255, 270, 285, 300, 315, 330, 345, 360, 375mm 9 10mm Dia 1 Each Length 255, 270, 285, 300, 315, 330, 345, 360, 375mm 9 11mm Dia 1 Each Length 255, 270, 285, 300, 315, 330, 345, 360, 375mm 9 Locking Screw 4.35mm Dia 2 Each Length 18, 20, 22, 24, 26, 28mm
4 Each Length 30, 32, 34, 36, 38, 40, 42, 44, 46, 48, 50, 52, 54, 56, 58, 60mm
2 Each Length 62, 64, 66, 68, 70, 72, 74, 76, 78, 80mm126420 Locking Screw 4.8mm Dia 4 Each Length 26, 28, 30, 32, 34, 36, 38, 40, 42, 44, 46, 48, 50, 52, 54, 56, 58, 60, 62mm
2 Each Length 62, 64, 66, 68, 70, 72, 74, 76, 78, 80, 85mm7622 4.8mm Cancellous Locking Screw (Dual Core) 6 Each Length 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90mm 84 End Caps 4 Each Extn 00, 0, 5, 10, 15 20 101.000 Empty Containder 1 -
Hip Screws, Ø 6.35mm for Recon Locking
Extn. in mm S.S TITANIUM 60 PF65-60 Ti-PF65-60 65 PF65-65 Ti-PF65-65 70 PF65-70 Ti-PF65-70 75 PF65-75 Ti-PF65-75 80 PF65-80 Ti-PF65-80 85 PF65-85 Ti-PF65-85 90 PF65-90 Ti-PF65-90 95 PF65-95 Ti-PF65-95 100 PF65-100 Ti-PF65-100 105 PF65-105 Ti-PF65-105 110 PF65-110 Ti-PF65-110 115 PF65-115 Ti-PF65-115 Drill Bit : 5.2mm
-
Perfect Femoral Nails
Our Perfect Femoral Nail with standard locking is indicated for fractures in femoral shaft and with Recon Locking for fractures in the femoral shaft in combination with femoral neck fractures. Additionally our Perfect Femoral Nail is indicated for fractures in the subtrochanteric section with :
Advanced Anatomical Nail Design : Optimal fit in bone & easier insertion and extraction. Titanium Alloy for improved mechanical and fatigue properties.
Optimized Locking Options : Standard Locking of femoral shaft fractures & Recon Locking in subtrochanteric fractures and comined femoral shaft and neck fractures.
Optimal Lateral entry point : Time saving surgical technique, Easier and safer access to entry site, Less soft tissue damage.
Improved Locking Options : Higher angular stability through multiplaner screws, less damage of soft tissues and improved mechanical resistance.
Anatomical Design with Right and Left Nail.
Use with Instrument Set – AS074
Footer
About Us
Libra Enterprises is a market leader in its segment in India and pioneers in delivering quality healthcare solutions employing ethical business practices. Read More
Contact
- Phone: +91 99928 45123, +91 8708642988, +91 1714000763
-
Fax:
- Email: info@libraexport.com, sales@libraexport.com
- Address: #1288,1st floor Opposite Hargolal post office Ambala cantt-133001 Haryana INDIA

Sending...

Reviews
There are no reviews yet.