Showing 91–99 of 123 results
Length in mm | S.S | Titanium |
---|---|---|
75 | 054-75 | Ti-054-75 |
80 | 054-80 | Ti-054-80 |
85 | 054-85 | Ti-054-85 |
90 | 054-90 | Ti-054-90 |
95 | 054-95 | Ti-054-95 |
100 | 054-100 | Ti-054-100 |
105 | 054-105 | Ti-054-105 |
110 | 054-110 | Ti-054-110 |
115 | 054-115 | Ti-054-115 |
Dia. in mm | Length in mm | S.S | Titanium |
---|---|---|---|
9 | 180 | TAN-9.180 | Ti-TAN-9.180 |
9 | 200 | TAN-9.200 | Ti-TAN-9.200 |
9 | 240 | TAN-9.240 | Ti-TAN-9.240 |
10 | 180 | TAN-10.180 | Ti-TAN-10.180 |
10 | 200 | TAN-10.200 | Ti-TAN-10.200 |
10 | 240 | TAN-10.240 | Ti-TAN-10.240 |
11 | 180 | TAN-11.180 | Ti-TAN-11.180 |
11 | 200 | TAN-11.200 | Ti-TAN-11.200 |
11 | 240 | TAN-11.240 | Ti-TAN-11.240 |
Use 4.8mm Locking Screw for Standard Locking
Use 6.35mm Hip Screws for Recon Locking
Note: Distal Jig will work upto the length of 440mm. For longer nails C arm is required for Distal Locking.
Use 4.8mm Locking Screw for Standard Locking
Use 6.35mm Hip Screws for Recon Locking
Note: Distal Jig will work upto the length of 440mm.For longer nails C arm is required for Distal Locking.
AS102 Perfect Femoral Nail Implants Set – For Right leg | |
---|---|
Set Consisting of : | Units |
Femoral Nails | |
9mm Dia | |
1 Each Length 320, 340, 360, 380, 400, 420, 440mm | 7 |
10mm Dia | |
1 Each Length 320, 340, 360, 380, 400, 420, 440mm | 7 |
11mm Dia | |
1 Each Length 320, 340, 360, 380, 400, 420, 440mm | 7 |
Locking Screw 4.8mm Dia | |
4 Each Length 26, 28, 30, 32, 34, 36, 38, 40, 42, 44, 46, 48, 50mm 2 Each Length 52, 54, 56, 58, 60, 62, 64, 66, 68, 70, 72, 74, 76, 78, 80, 85 |
5232 |
Hip Screw 6.35mm Dia | |
2 Each Length 60, 65, 70mm 4 Each Length 75, 80, 85, 90, 95, 100, 105, 110, 115mm |
636 |
End Caps | |
2 Each Extn 0, 5, 10, 15, 20 | 10 |
102.000 Empty Containder | 1 |
Our Perfect Femoral Nail with standard locking is indicated for fractures in femoral shaft and with Recon Locking for fractures in the femoral shaft in combination with femoral neck fractures. Additionally our Perfect Femoral Nail is indicated for fractures in the subtrochanteric section with :
Advanced Anatomical Nail Design : Optimal fit in bone & easier insertion and extraction. Titanium Alloy for improved mechanical and fatigue properties.
Optimized Locking Options : Standard Locking of femoral shaft fractures & Recon Locking in subtrochanteric fractures and comined femoral shaft and neck fractures.
Optimal Lateral entry point : Time saving surgical technique, Easier and safer access to entry site, Less soft tissue damage.
Improved Locking Options : Higher angular stability through multiplaner screws, less damage of soft tissues and improved mechanical resistance.
Anatomical Design with Right and Left Nail.
Use with Instrument Set – AS074
Our Perfect Tibial Nail is indicated for fractures in the Tibial Shaft as well as for Metaphyseal and certain intraarticular fracture of the tibial head and pilon tibaile with :